Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
3241988 | Injury | 2010 | 5 Pages |
AimThe aim of the present study was to compare the primary fixation stability and initial fixation stiffness of two established fixation techniques, the tension band wiring technique and interfragmentary screw fixation, with a mini-screw fragment fixation system in a model of transverse patella fracture. It was hypothesised that the biomechanical loading performance of the fragment fixation system would not significantly differ from the loading characteristics of the two established methods currently investigated.Materials and methodsNinety-six calf patellae were used in this biomechanical model. A standardized transverse patella fracture was induced and three different fixation methods, including the modified tension band wiring technique, interfragmentary screw fixation, and the mini-screw fragment fixation system, were used for fragment fixation. Specimens were mounted to a loading rig which was secured within a material testing machine. In each fixation group, eight specimens were loaded to failure at a simulated knee angle of either 0° or 45°. Another eight specimens were submitted to a polycyclic loading protocol consisting of 30 cycles between 20 N and 300 N at a simulated knee angle of 0° or 45°. The residual displacement between the first and the last cycle was recorded. Differences in the biomechanical performance between the three fixation groups were evaluated.ResultsNo significant differences between the three fixation groups were observed in the parameters maximum load to failure and linear fixation stiffness with monocyclic loading. Specimens being loaded at 45° showed significantly lower maximum failure loads and linear stiffness when compared with 0°. During polycyclic loading, no significant differences in the residual displacement were observed between the groups at 0° loading angle, while at 45°, residual displacement was significantly higher with tension band fixation when compared with interfragmentary screw fixation or the fragment fixation system.ConclusionThe biomechanical performance of the fragment fixation system was comparable to interfragmentary screw fixation and superior to the tension band wiring technique. Given the advantages of a system which provides interfragmentary compression and which simplifies fracture fixation after open or closed reduction, we believe the fragment fixation system to be an adequate alternative in the osteosynthesis of transverse patella fractures.