Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
387657 | Expert Systems with Applications | 2012 | 9 Pages |
This paper proposes the application of fault-tolerant control (FTC) using fuzzy predictive control. The FTC approach is based on two steps, fault detection and isolation (FDI) and fault accommodation. The fault detection is performed by a model-based approach using fuzzy modeling and fault isolation uses a fuzzy decision making approach. The information obtained on the FDI step is used to select the model to be used in fault accommodation, in a model predictive control (MPC) scheme. The fault accommodation is performed with one fuzzy model for each identified fault. The FTC scheme is used to accommodate the faults of two systems a container gantry crane and three tank benchmark system. The fuzzy FTC scheme proposed in this paper was able to detect, isolate and accommodate correctly the considered faults of both systems.