Article ID Journal Published Year Pages File Type
398484 International Journal of Electrical Power & Energy Systems 2016 7 Pages PDF
Abstract

•The combined model of LFC–AVR in multi source multi area system is developed.•Non-linear system operating under unequal area capacities is considered.•On load disturbance the frequency, tie-line power & voltage changes are examined.•PID controller is tuned using ZN and SA technique.•SA tuned PID controller is proposed in retaining the system to nominal value.

The article proposes optimal secondary controller for combined Load Frequency Control (LFC) and Automatic Voltage Regulation (AVR) of multi source multi area system using simulated annealing technique. When subjected to load disturbance, frequency, tie-line power and voltage fluctuations results higher oscillations. Speed governor of the system helps to match generation with the demand. But, fine tuning of frequency, tie-line power and voltage when subjected to load disturbance in multi source multi area system is achieved by secondary Proportional Integral Derivative (PID) controller. As a conventional benchmark PID controller is tuned using Zeigler Nichol’s (ZN) method and further optimized using Simulated Annealing (SA) technique. The performance of the system is validated and judged using performance indices.

Graphical abstractFigure optionsDownload full-size imageDownload as PowerPoint slide

Related Topics
Physical Sciences and Engineering Computer Science Artificial Intelligence
Authors
, ,