Article ID Journal Published Year Pages File Type
467296 Computer Methods and Programs in Biomedicine 2006 8 Pages PDF
Abstract

One of the major causes inducing loosening in the cementless acetabular cup implanting is its insufficient initial stability. In this study, three-dimensional finite element models of the pelvis and acetabular components were developed to investigate the relationship between relative micromotion, initial stability, and screw fixation under six daily activity loadings. A commercial available hemispheric cup with five screw holes was used as the target acetabular cup. The simulation results showed that if screws were placed closed together, when the screw number increased from 1 to 5, the peak micromotion decreased less than 14%, from 126.5 to 108.8 μm, while the stable region, micromotion less than 28 μm, enlarged only by 40%, from 46.1% to 64.7%. However, if the screw could be placed near the cup rim, a single rim screw, 202.1 μm micromotion, could provide better stability than that of four dome screws, 209.6 μm micromotion, placed closed together. To conclude, multiple cup screws should be placed near cup rim and as separate as possible to enlarge the stable region and reduce the peak micromotion between cup and acetabulum.

Related Topics
Physical Sciences and Engineering Computer Science Computer Science (General)
Authors
, , , , , , ,