Article ID Journal Published Year Pages File Type
480939 European Journal of Operational Research 2011 14 Pages PDF
Abstract

In order to design a coverage-type service network that is robust to the worst instances of long-term facility loss, we develop a facility location–interdiction model that maximizes a combination of initial coverage by p facilities and the minimum coverage level following the loss of the most critical r facilities. The problem is formulated both as a mixed-integer program and as a bilevel mixed-integer program. To solve the bilevel program optimally, a decomposition algorithm is presented, whereby the original bilevel program is decoupled into an upper level master problem and a lower level subproblem. After sequentially solving these problems, supervalid inequalities can be generated and appended to the upper level master in an attempt to force it away from clearly dominated solutions. Computational results show that when solved to optimality, the bilevel decomposition algorithm is up to several orders of magnitude faster than performing branch and bound on the mixed-integer program.

Related Topics
Physical Sciences and Engineering Computer Science Computer Science (General)
Authors
, ,