Article ID Journal Published Year Pages File Type
4976529 Journal of the Franklin Institute 2008 17 Pages PDF
Abstract
This paper investigates rotor-side field oriented control of a wound-rotor induction motor using the slip energy recovery principle. The proposed drive system uses a matrix converter to transfer the slip energy from the rotor into the mains instead of using ac-dc-ac converter whilst the stator side is fixed to the grid. Operation at both subsynchronous and supersynchronous regions is possible with the proposed drive system. Simulation studies of the proposed doubly fed induction motor drive system verify the good control performance of the system in transient and steady-state conditions.
Related Topics
Physical Sciences and Engineering Computer Science Signal Processing