Article ID Journal Published Year Pages File Type
4991165 Applied Thermal Engineering 2017 30 Pages PDF
Abstract
This paper presents the modeling and thermodynamic analysis of different heat transformers configurations using the alternative mixture NH3-LiNO3. The analyzed configurations are: (i) Absorption Heat Transformer (AHT), (ii) Double Absorption Heat Transformer (DAHT), (iii) Resorption Heat Transformer (RHT) and (iv) Double Resorption Heat Transformer (DRHT). Coefficients of performance and exergetic efficiencies are reported for each one of the systems as function of the main system temperatures. The results showed that the coefficients of performance and exergetic efficiencies are higher for the conventional cycles without the resorption circuit (AHT and DAHT), however, their operating pressures are considerable higher than those reached with the systems with the resorption circuit.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes