Abstract
A thermal evaluation of a four configurations of double glass window (DGW) coupling to a room is presented. The DGW consists of two vertical semitransparent walls separated by a 12 mm air gap. The effect of varying the ambient temperature and the incident solar radiation in the warm climate conditions in México is analyzed. Numerical simulations were conducted for four configurations; Case 1: clear glass + air gap + clear glass (Reference); Case 2: clear glass + air gap + absorbent glass; Case 3: clear glass + air gap + Low-e glass; and Case 4: clear glass + air gap + reflective glass. Optical transmittance and specular reflectance were measured individually and in one sample piece for each case. The results showed that Case 4 reduces the heat flux to the indoors by up to 73%, with respect to Case 1. Moreover, Cases 2 and 3 had a similar behavior, obtaining a reduction of indoor heat flow close to 33.5% with respect to Case 1. Case 4 is the best option for energy savings in a warm climate, where it is possible to save up to $20.29 USD per kW h per year, in comparison to Case 1. In addition, the payback period for Case 4 is 3.7 years. Therefore, the use of reflective double pane window is highly recommended in Mexican warm climates.