Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4991566 | Applied Thermal Engineering | 2017 | 39 Pages |
Abstract
The low-temperature ash deposition and dewpoint corrosion of three materials were studied under six tube wall temperatures in a coal-fired travelling grate boiler. The experimental and simulation results showed that the leeward sides of the test sections were prone to suffer serious ash deposition and corrosion caused by acid condensation. The ash deposition and corrosion characteristics were different in various wall temperature ranges and the mechanisms were discussed. The corrosion resistance of the three tested materials was as follows: 316Â LÂ >Â NDÂ >Â 20#. Recommendations were given to choose the materials for the waste heat recovery of coal-fired travelling grate boilers.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Heng Chen, Peiyuan Pan, Jian Jiao, Yungang Wang, Qinxin Zhao,