Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4991586 | Applied Thermal Engineering | 2017 | 20 Pages |
Abstract
In the temperature distribution in a hot-side displacer chamber of a low temperature differential Stirling engine, a relation between the inlet temperature, average temperature and heat exchanger temperature is calculated by CFD and is expressed by the ratio of temperatures. The parameters of the CFD are the inlet velocity; the sizes of the inlet, heat exchanger and displacer; the positions of the inlet, heat exchanger and displacer chamber wall; and the temperatures of the inlet and heat exchanger. The calculation result and the estimated regenerator efficiency produce the temperature difference in the working fluid, which can be utilized for isothermal model analysis. In the Schmidt cycle, only a phase angle and the dimensionless value introduced here dominate the shape of the P-V diagram. The maximum fluctuation of the ensemble averaged working fluid temperatures (MFEAWFTs) is utilized to evaluate a P-V diagram. When the analyses are compared with experimental results, estimated MFEAWFTs are approximately 80% of the experimental results. In comparing the calculation results, a higher engine speed causes a lower average temperature on the hot side of a displacer chamber and the larger indicated power. A wider inlet reduces the difference between inlet temperature and average temperature. The longer stroke of displacer motion makes the indicated work larger to some extent.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Yoshitaka Kato, Shinichi Saitoh, Katsuya Ishimatsu, Mitsuo Iwamoto,