Article ID Journal Published Year Pages File Type
4992040 Applied Thermal Engineering 2017 11 Pages PDF
Abstract
In this paper, a comprehensive method containing cold-state modeling experiment, cold-state numerical simulation, and hot-state numerical simulation is employed to analyze the aerodynamic field in a 600 MWe tangentially fired pulverized boiler. To investigate the non-uniformity characteristics of flow field distribution in the horizontal flue under deep air-staged condition by this method, a major attention is paid to the gas velocity deviation in front of the final super-heater. Experiments at the cases of various yaw angles of separate over-fire air (SOFA) are carried out under a cold model of the large utility boiler with a roughly 1:28 scale. And the cold model is equipped with 3D-printed nozzles arranged in the four corners. Moreover, the corresponding cases are conducted by cold-state numerical simulation in the cold model furnace, and hot-state numerical simulation in the original furnace. The results show that the experimental data are in general agreement with simulated results in the cold modeling furnace. And through comparison of velocity profile at the same dimensionless furnace height, the results of cold-state model show the similar characteristics of gas velocity distribution that presented in the hot-state situation of the original furnace. Thus, through reasonable cold-state modeling, a detailed velocity distribution can be obtained to give a good insight into the gas velocity deviation characteristics in the horizontal flue.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes