Article ID Journal Published Year Pages File Type
508603 Computers in Industry 2013 8 Pages PDF
Abstract

To register 3D meshes representing smooth surfaces we track the 3D digitization system using photogrammetric techniques and calibrations. We present an example by digitizing a 800 mm × 600 mm portion of a car door. To increase the tracking accuracy the 3D scanner is placed in a cubic frame of side 0.5 m covered with 78 targets. The target frame moves in a volume that is approximately 1100 mm × 850 mm × 900 mm, to digitize the area of interest. Using four cameras this target frame is tracked with of an accuracy of 0.03 mm spatially and 0.180 mrad angularly. A registration accuracy between 0.1 mm and 2 mm is reached. This method can be used for the registration of meshes representing featureless surfaces.

Related Topics
Physical Sciences and Engineering Computer Science Computer Science Applications
Authors
, , , ,