| Article ID | Journal | Published Year | Pages | File Type |
|---|---|---|---|---|
| 5145303 | International Journal of Hydrogen Energy | 2017 | 10 Pages |
Abstract
The solution also revealed a coefficient that relates the current, flow rate, and membrane diffusion in a single term. This coefficient could be used for control decisions to avoid flooding issues in the stack. Furthermore, using the analytical RH profile equation, CVs can be optimally, unevenly sized to improve the modeling of local operating conditions.
Related Topics
Physical Sciences and Engineering
Chemistry
Electrochemistry
Authors
Alexander J. Headley, Dongmei Chen, Wei Li,