Article ID Journal Published Year Pages File Type
5550833 International Journal of Pharmaceutics 2016 11 Pages PDF
Abstract

The goal of this work was to evaluate the ability of Particle Image Velocimetry (PIV) to visually assess dry powder dispersion within an inhaler. Herein, the study reports particle movement characterization of entrained low-micron particles within an inhaler to further scheme of potential mechanisms. Carrier based DPI formulations were prepared and placed in a transparent model Rotahaler® chamber for the aerosolization experiments. Then using the PIV, a high-speed camera, the dried powder dispersion was directly observed and analyzed for all, neat, binary and ternary systems. Powder dispersion mechanisms proposed include drag force, impact with obstacle and particle-particle collision; these different mechanisms depended on the powder flow properties. A revised ratio of aerodynamic response time (τA) to the mean time between collisions (τC) was found to be 6.8 indicating that particle collisions were of strong influence to particle dispersion. With image analysis techniques, visualization of particle flow pattern and collision regions was possible; suggesting that the various mechanisms proposed did govern the powder dispersion.

Graphical abstractDownload high-res image (141KB)Download full-size image

Related Topics
Health Sciences Pharmacology, Toxicology and Pharmaceutical Science Pharmaceutical Science
Authors
, , , , ,