Article ID Journal Published Year Pages File Type
558818 Biomedical Signal Processing and Control 2014 10 Pages PDF
Abstract

BackgroundMinimizing excessive postprandial glucose excursion is still an unmet need in treating diabetes. This work addresses the analysis and modeling in the postprandial state of two commercial CGM devices.MethodsTwelve patients with type 1 diabetes were studied in the postprandial state on four different occasions under controlled conditions. Each time, we performed simultaneous glucose monitoring using the Dexcom SEVEN® PLUS (47 datasets) and the Medtronic Paradigm® Veo™ (42 datasets). The following statistical properties of the error signal were analyzed and modeled sequentially for the two devices: the lag time, the error stationarity, the error probability distribution and the time correlation. Finally, models were built for sensor simulation in silico studies.ResultsLag time followed an exponential probability distribution for both monitors (μsevenplus = 108, μveo = 1.69). Standard deviation and mean of the error signal, calculated as time-dependent signals across the population of sensors, were time-varying and correlated with the reference value and its rate of change, respectively. In both cases, a high variability of postprandial behaviors was observed. After non-stationarity compensation, a logistic distribution was obtained for the SEVEN® PLUS error (close to normal distribution). Regarding the Paradigm® Veo™, a multimodal distribution was obtained, which turned into normal after elimination of five “unstable” sensors. Finally, a first order autoregressive model fitted the SEVEN® PLUS error time-series while a third-order filter was necessary for the Paradigm® Veo™.ConclusionsThe Paradigm® Veo™ device exhibited greater delay variability with higher delay time and higher probability of abnormal sensor behaviors as compared to the SEVEN® PLUS device. In both cases, the observed variability may have important clinical implications in postprandial performance. Therefore, further improvements are needed in calibration algorithms to reduce this variability.

► 12 diabetic patients were monitored simultaneously with 2 commercial CGM. ► Analysis and comparison of postprandial error of the devices was performed. ► Delay, stationarity, probability distribution and correlations were modeled. ► High variability and non-stationarity of the error was observed. ► Simulation models were built for its use in in silico studies.

Related Topics
Physical Sciences and Engineering Computer Science Signal Processing
Authors
, , , , ,