Article ID Journal Published Year Pages File Type
566116 Speech Communication 2010 13 Pages PDF
Abstract

The physical characteristics of weak body-conducted vocal-tract resonance signals called non-audible murmur (NAM) and the acoustic characteristics of three sensors developed for detecting these signals have been investigated. NAM signals attenuate 50 dB at 1 kHz; this attenuation consists of 30-dB full-range attenuation due to air-to-body transmission loss and −10 dB/octave spectral decay due to a sound propagation loss within the body. These characteristics agree with the spectral characteristics of measured NAM signals. The sensors have a sensitivity of between −41 and −58 dB [V/Pa] at 1 kHz, and the mean signal-to-noise ratio of the detected signals was 15 dB. On the basis of these investigations, three types of silent-speech enhancement systems were developed: (1) simple, direct amplification of weak vocal-tract resonance signals using a wired urethane-elastomer NAM microphone, (2) simple, direct amplification using a wireless urethane-elastomer-duplex NAM microphone, and (3) transformation of the weak vocal-tract resonance signals sensed by a soft-silicone NAM microphone into whispered speech using statistical conversion. Field testing of the systems showed that they enable voice impaired people to communicate verbally using body-conducted vocal-tract resonance signals. Listening tests demonstrated that weak body-conducted vocal-tract resonance sounds can be transformed into intelligible whispered speech sounds. Using these systems, people with voice impairments can re-acquire speech communication with less effort.

Keywords
Related Topics
Physical Sciences and Engineering Computer Science Signal Processing
Authors
, , , , , , ,