Article ID Journal Published Year Pages File Type
5867479 American Journal of Infection Control 2016 5 Pages PDF
Abstract

•We examine 2 deployments of pulsed xenon ultraviolet disinfection: all discharges (intensive care unit) and Clostridium difficile isolation only (nonintensive care unit).•Use of pulsed xenon ultraviolet disinfection was associated with reductions in hospital-acquired infection rates.•Over 400 rooms per month were disinfected with pulsed xenon ultraviolet disinfection.•Pulsed xenon ultraviolet disinfection was run in three 5-minute positions in each room.

BackgroundThe role of contaminated environments in the spread of hospital-associated infections has been well documented. This study reports the impact of a pulsed xenon ultraviolet no-touch disinfection system on infection rates in a community care facility.MethodsThis study was conducted in a community hospital in Southern Florida. Beginning November 2012, a pulsed xenon ultraviolet disinfection system was implemented as an adjunct to traditional cleaning methods on discharge of select rooms. The technology uses a xenon flashlamp to generate germicidal light that damages the DNA of organisms in the hospital environment. The device was implemented in the intensive care unit (ICU), with a goal of using the pulsed xenon ultraviolet system for disinfecting all discharges and transfers after standard cleaning and prior to occupation of the room by the next patient. For all non-ICU discharges and transfers, the pulsed xenon ultraviolet system was only used for Clostridium difficile rooms. Infection data were collected for methicillin-resistant Staphylococcus aureus, C difficile, and vancomycin-resistant Enterococci (VRE). The intervention period was compared with baseline using a 2-sample Wilcoxon rank-sum test.ResultsIn non-ICU areas, a significant reduction was found for C difficile. There was a nonsignificant decrease in VRE and a significant increase in methicillin-resistant S aureus. In the ICU, all infections were reduced, but only VRE was significant. This may be because of the increased role that environment plays in the transmission of this pathogen. Overall, there were 36 fewer infections in the whole facility and 16 fewer infections in the ICU during the intervention period than would have been expected based on baseline data.ConclusionImplementation of pulsed xenon ultraviolet disinfection is associated with significant decreases in facility-wide and ICU infection rates. These outcomes suggest that enhanced environmental disinfection plays a role in the risk mitigation of hospital-acquired infections.

Related Topics
Life Sciences Immunology and Microbiology Microbiology
Authors
, , , , , ,