Article ID Journal Published Year Pages File Type
6130530 Clinical Microbiology and Infection 2014 8 Pages PDF
Abstract
The European Committee on Antimicrobial Susceptibility Testing (EUCAST) began harmonizing clinical breakpoints in Europe 2002. In 2009, work to develop a disc diffusion method began and the first disc diffusion breakpoints calibrated to EUCAST clinical MIC breakpoints were published in December 2009. In this study we validated EUCAST clinical zone diameter breakpoints against the International Standard Organization (ISO) reference broth microdilution. A collection of 544 isolates (238 Gram-negative and 306 Gram-positive) were tested against a panel of antimicrobial agents. Antimicrobial susceptibility testing was performed with broth microdilution as described by ISO and disc diffusion in accordance with EUCAST methodology. Inhibition zone diameters and MIC values were interpreted and categorized (S, I and R) according to EUCAST clinical breakpoint table version 2.0. Categorical agreement (CA) as well as minor (mD), major (MD) and very major (VMD) discrepancies were determined. There was in general good correlation between susceptibility test results obtained with disc diffusion and broth microdilution. Overall CA was 97.3% for all combinations of organisms and antimicrobial agents (
Related Topics
Life Sciences Immunology and Microbiology Microbiology
Authors
, , ,