Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
620442 | Chemical Engineering Research and Design | 2015 | 11 Pages |
Abstract
- We measured the flow field in the rotor of ACC with PIV technique.
- Flow field with different rotational speed and flow rate were tested.
- The rotational speed had a significantly impact on the velocity.
- The flow rate had less effect on the tangential velocity and radial velocity.
- Vortexes formed in the rotational reference frame demonstrated CFD simulations.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Yan Xu, Jian-gang Wang, Shuang-liang Zhao, Zhi-shan Bai,