Abstract
Liquid holdup is an important hydrodynamic parameter for characterizing the gas/liquid flow pattern in packed beds. In this paper, a study of liquid holdup in 3 different structured packings: Mellapak 2X from Sulzer, Koch-Glitsch Flexipac 2Y HC, and Montz-Pak B1-250M is presented, using air/water, air/water/sugar solutions with liquid viscosity up to 12Â cP and air/30Â wt% MEA in a 0.5Â m ID absorption column with a packing height of 5Â m. As expected, at a given liquid load, the liquid holdup was close to constant as a function of gas flow, with an increase at high gas velocities. In general, the Sulzer packing had a higher liquid holdup than observed in the two other packings. A possible explanation for this could be the lack of enhanced draining of liquid as seen with the modifications of the end-section of the Koch-Glitsch and Montz packings. Liquid holdup was found to increase with increasing liquid viscosity. The influence was higher at high liquid load than at low liquid load. Our results indicate a higher dependency at high liquid load and a lower at low liquid load. There was a reasonable agreement between our results and the data found in the literature.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Ali Zakeri, Aslak Einbu, Hallvard F. Svendsen,