Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
622042 | Chemical Engineering Research and Design | 2011 | 13 Pages |
Abstract
â¶ HYSYS simulator can successfully optimize the amine based post combustion CO2 capture. â¶ There is an optimal composition of MDEA and DEA amines which minimize the total cost. â¶ The optimal concentration is: 20% MDEA and 20% DEA in water (wet weight).
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Patricia Mores, Nicolas Scenna, Sergio Mussati,