Article ID Journal Published Year Pages File Type
622600 Chemical Engineering Research and Design 2006 11 Pages PDF
Abstract
Grade efficiency was determined for the improved cyclone design operating over a range of gas flowrates. The cut size for outflow to the vortex finder was found to vary from about 7 μm at an air velocity of 4.5 ms−1 to about 4.5 μm at 11 ms−1.
Related Topics
Physical Sciences and Engineering Chemical Engineering Filtration and Separation