Article ID Journal Published Year Pages File Type
644730 Applied Thermal Engineering 2016 5 Pages PDF
Abstract

•Quantitative detection of TBC thickness has been carried out.•The model of heat conduction inverse problem was built.•The basic principle and implementation process of SA algorithm was described.

Quantitative detection of thermal barrier coating thickness based on simulated annealing (SA) algorithm has been carried out using pulsed infrared thermography technology. The principle of quantitative detection of thermal barrier coating thickness was given, and the model of inverse heat conduction problem was built. The basic principle and implementation process of SA algorithm was described. The specimen with uneven coating thickness was detected using pulsed infrared thermography system, and the coating thickness was calculated using SA algorithm. Results show that when the coating thickness is 45~130 µm, compared with eddy current testing results, the relative error is less than 10%, which proves the effectiveness of the coating thickness detection method proposed in this paper.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , , , ,