Article ID Journal Published Year Pages File Type
644970 Applied Thermal Engineering 2016 28 Pages PDF
Abstract

- The multi-hole (mh) spray morphology is very similar to that of single-hole nozzles.
- Unsteady spray was found at low pressure and low gas-to-liquid-ratio (GLR) values.
- Cone angle variation in mh spray with pressure and GLR depends on the exit nozzles angle.
- A liquid-gas gravitational separation in horizontal atomiser operation was observed.
- It causes up to 70% fuel supply variance into exit holes depending on design and regime.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, ,