Article ID Journal Published Year Pages File Type
645871 Applied Thermal Engineering 2015 9 Pages PDF
Abstract
In this paper the results from a measurement campaign in a steam boiler affected by excessive deposits are presented and compared against the manufacturer's operating data. A number of differences were found between the two sets of data and were attributed to the particulars of excessive amount of deposits in the boiler. In addition, the present study investigates the chemical composition and behavior of the slagging and fouling deposits that occur in units of the Kardia power plant as well as of a bottom ash and a fly ash sampled from the same unit. The steam path of the unit was simulated using the DNA software in order to model the effect of the contamination on the global performance parameters of the power plant and the results were compared against the experienced operational performance parameters. In addition, a number of practices are proposed and assessed for reducing the levels of boiler contamination and extending the time between successive maintenance stoppages.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , ,