Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
645879 | Applied Thermal Engineering | 2015 | 13 Pages |
Abstract
The present study focuses on the use of lubricating oil as a coolant for electrical motors. Oil is introduced at each side of a 40Â kW test machine to directly cool the stator coil end-windings. An experimental setup has been implemented to test different oil injection patterns. The influence of the oil flow rate, rotation speed and oil temperature has been investigated (40Â L/hÂ
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Tanguy Davin, Julien Pellé, Souad Harmand, Robert Yu,