Article ID Journal Published Year Pages File Type
646756 Applied Thermal Engineering 2013 7 Pages PDF
Abstract

On the basic principle of stepless capacity control system for large reciprocating compressor, the thermal cycle was analyzed. The equations for the process of suction, reverse flow, compression, discharge and expansion of clearance gas were established. According to these equations, p–V diagrams at various situations were simulated. An experimental platform was setup and the compressor with designed stepless capacity control system run well. The experimental results show that the capacity of compressor can be regulated steplessly, and the motor power is reduced proportionally with respect to the reduction of capacity. During the suction process, both the flow resistance of valve and the pressure fluctuation in cylinder can be reduced by opening the suction valves with the actuators. The simulated and experimental results showed good coincidence. The clearance volume and valve clearance Mach number had a negative influence on the thermal performance of compressor with stepless capacity control system.

► Flow resistance of valve can be reduced and pressure fluctuation can be reduced. ► Equivalent Mach number of reverse flow is much higher than that of suction process. ► Response of stepless capacity control system is important for regulation accuracy. ► Clearance and valve clearance Mach number have influence on thermal performance.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , , , , , , ,