Abstract

Nowadays multiple effect desalination plants are used widely in water treatment processes. They utilize thermal vapor compressors instead of mechanical ones. One of the major complexities about thermo-compressors is related to its unstable operational mode. An experimental malfunctioning occurred in a desalination unit established in south pars gas field phases 9&10 with 1718 cubic meter per day capacity. Some modifications on the thermo-compressor design were applied and well tested.In the current study a numerical investigation was performed on a malfunctioning thermo-compressor and the source of the problem was observed via a numerical simulation. Afterwards, the modifications were conducted on the numerical models and then a perfect analyzed and verified model was selected to manufacture and install. The test results were shown a better performance of thermo-compressor which yields an increase in entrainment ratio and extend the stable region of thermo-compressor working. It is shown that the entrainment ratio is very sensitive to the geometrical parameters of mixing area zone and throat section of thermo-compressor.

► Thermo-compressor should be designed in double choking mode in the worst case. ► Thermo-compressor maximum discharge pressure is very sensitive to the mixing angle. ► Low mixing angle causes to increase the mixing efficiency of thermo-compressors.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, ,