Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
647711 | Applied Thermal Engineering | 2011 | 11 Pages |
Abstract
⺠Heat transfer enhancements of heat pipe fin stacks was successfully achieved using fixed and active delta wing vortex generators. ⺠The active vortex generators, made from Ti-Ni, protruded into the flow stream at high temperatures and resume a low profile position at a low temperature set point. ⺠By considering wing spacing and the distance from the leading edge of the fin stack, heat transfer enhancements of up to 37%, compared to plane fin stacks, were achieved. ⺠By replacing the fixed delta wings with the active vortex generators, heat transfer enhancements of up to 16% was achieved and the pressure loss associated with flow obstructions was effectively managed.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
M.S. Aris, R. McGlen, I. Owen, C.J. Sutcliffe,