Article ID Journal Published Year Pages File Type
648776 Applied Thermal Engineering 2009 10 Pages PDF
Abstract
Thermal entrainment factor (TEF) is an important parameter to describe the cold preservation performance of a display cabinet. In order to calculate the TEF of a display cabinet rapidly and accurately, the method of establishing a correlation model based on computational fluid dynamics (CFD) simulation results is presented and the correlation model of TEF for typical single and double air curtain in a vertical open display cabinet is developed in this paper. The TEF of display cabinet predicted by the correlation model gives a maximum deviation of −9.4% and a mean deviation of −0.1% compared with the published experimental data. In addition, the correlation model can be used to calculate the air curtain return temperature, showing a maximum deviation of 0.9 °C and an average deviation of 0.1 °C compared with the published experimental data.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes