Article ID Journal Published Year Pages File Type
649479 Applied Thermal Engineering 2005 12 Pages PDF
Abstract

This paper presents new results for confined and unconfined boiling of FC72 and FC87 at atmospheric pressure and low and moderate heat fluxes—lower than 45 kW/m2—on a downward-facing disc placed at 0.2, 0.5, 1 and 13 mm distance from the base of a boiling chamber, corresponding to Bond numbers 0.28, 0.69, 1.38 and 17.95. The experimental results showed enhanced boiling as the main trend for the cases with s = 0.2 and 0.5 mm compared with those with s = 1 and 13 mm and a higher heat-transfer coefficient for FC72 boiling compared with FC87, with a wall superheating of 7.7–8 K higher for FC87.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , ,