Article ID Journal Published Year Pages File Type
649586 Applied Thermal Engineering 2008 8 Pages PDF
Abstract

The mathematical control model for dynamic start-up process of the VTE-MED seawater desalination system was established employing the previous developed non-linear differential equations for system design and performance analysis. The influences on the start-up process of the operating parameters, such as the initial feed brine flow rate and the top brine temperature were analyzed. The relationships among the feed brine flow rate, the gained output ratio (GOR) and the start-up time were also investigated, which can be evidence to determine the optimal initial feed brine flow rate. The results also indicate that the system can consume the total heat rating generated by the low temperature nuclear heating reactor (LT-NHR) even at the most initial start-up stage, implying the present desalination system has excellent coupling characteristics with the LT-NHR. With necessary experiments verifications, the start-up control model developed in this paper can be the theoretical base for the analysis of dynamic performances of the seawater desalination system.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , , ,