The present paper reports the results of an experimental investigation on saturated pool boiling heat transfer of R134a on High-Flux, Gewa-B, Turbo-CSL and Turbo-BII HP tubes. Experiments have been carried out at saturation temperatures of 5, 10 and 20 °C and heat fluxes from 20 to 70 kW/m2. At most of the experimental conditions tested, an almost negligible effect of the saturation temperature on the heat transfer coefficient was found. Except for Turbo-CSL, the heat transfer coefficient presented either a slight decrease in its value or an almost constant value with increasing heat flux. The heat transfer enhancement ratios of the High-Flux, Gewa-B, Turbo-CSL and Turbo-BII HP tubes were 4.9–21.3, 2.4–5.2, 2.4–2.9 and 1.8–7.0, respectively, compared to a plain tube.