Article ID Journal Published Year Pages File Type
649931 Applied Thermal Engineering 2005 11 Pages PDF
Abstract

This paper proposes a circulating system for a steam jet refrigeration system that does not require mechanical power. In this system, the liquid from the condenser is fed to the boiler by means of the boiler pressure and gravity force. This feeding system was tested separately. It was found that the heat input to the boiler was relatively similar to the one in a conventional system using a mechanical pump. The steam jet refrigerator employing this workless boiler feeding system was also tested. It was shown that this system gave a similar COP to that from a system using a mechanical pump.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, ,