Article ID Journal Published Year Pages File Type
6680562 Applied Energy 2018 13 Pages PDF
Abstract
As interest in the distributed generation of solar power system in a building façade continues to increase, its technical performance (i.e. the amount of electricity generation) should be carefully investigated before its implementation. In this regard, this study aimed to develop the nine-node-based finite element model for estimating the technical performance of the distributed generation of solar power system in a building façade (FEM9-node), focusing on the improvement of the prediction performance. The developed model (FEM9-node) was proven to be superior to the four-node-based model (FEM4-node), which was developed in the previous study, in terms of both prediction accuracy and standard deviation. In other words, the prediction accuracy (3.55%) and standard deviation (2.93%) of the developed model (FEM9-node) was determined to be superior to those of the previous model (FEM4-node) (i.e. 4.54% and 4.39%, respectively). The practical application was carried out to enable a decision maker (e.g. construction manager, facility manager) to understand how the developed model works in a clear way. It is expected that the developed model (FEM9-node) can be used in the early design phase in an easy way within a short time. In addition, it could be extended to any other countries in a global environment.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,