Article ID Journal Published Year Pages File Type
6681813 Applied Energy 2017 12 Pages PDF
Abstract
The objective of this paper is a detailed evaluation of regenerators as a competing technology for recuperators within an sCO2 Brayton cycle. The level of the analysis presented here is sufficient to identify issues with the regenerator system in order to direct future work and also to clarify the potential advantage of pursuing this technology. A reduced order model of a regenerator is implemented into a cycle model of an sCO2 Brayton cycle. An economic analysis investigates the cost savings that is possible by switching from recuperative heat exchangers to switched-bed regenerators. The cost of the regenerators was estimated using the amount of material required if the pressure vessel is sized using ASME Boiler Pressure Vessel Code (BPVC) requirements. The cost of the associated valves is found to be substantial for the regenerator system and is estimated in collaboration with an industrial valve supplier. The result of this analysis suggests that a 21.2% reduction in the contribution to the Levelized Cost of Electricity (LCoE) from the power block can be realized by switching to a regenerator-based system.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,