Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6682594 | Applied Energy | 2016 | 15 Pages |
Abstract
In this work, a novel detailed mathematical model for the performance assessment of diabatic compressed air energy storage (D-CAES) systems with underground storage site is proposed. The model was implemented in Matlab environment and it was validated using the D-CAES Huntorf plant data, demonstrating a close agreement with the data reported in literature. The analysis of some case studies of the D-CAES plant showed that the characteristic curves of the compressors, that were assumed for the operation in steady state conditions, are not suitable for modeling the operation in time-dependent conditions. Thus, different characteristic curves of the compressors and turbines were identified in such a way that the operation points of turbomachinery lay within the admissible range during the entire process sequence, in steady state or time-dependent conditions. Furthermore, the analysis demonstrated that the presence of the throttling valves in the charging and discharging circuits is preferable due to a higher simplicity of construction and regulation despite a low increase of the fuel consumption in the combustion chambers.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Stefano Briola, Paolo Di Marco, Roberto Gabbrielli, Juri Riccardi,