Article ID Journal Published Year Pages File Type
6688629 Applied Energy 2014 13 Pages PDF
Abstract
It has been found that the hourly values of the cover factors (namely, the load cover factor and the supply cover factor) provide quite a good picture of the correlation between on-site demand and supply of energy. These factors illustrate both the daily and seasonal effect, the production pattern of different renewable energy technologies, and applied operation/control strategies. The loss-of load probability factor shows how often the on-site supply does not cover the on-site demand but it provides limited information. Several grid interaction indicators are presented in a normalized form based on the connection capacity between the building and the grid. The generation multiple is an index that compares peak values of exported/imported energy; it may also be used with generation/load values. The dimensioning rate and the connection capacity credit relate the building with the electrical grid. These indexes can be used to analyze individual buildings and extend their use in the case of cluster of buildings. Although some general trends have been identified in the results and the usefulness of these indicators is demonstrated, it should be noted that further studies are needed in order to define reference values for particular building topologies, clusters of buildings and climates, which could be used as a rule-of-thumb for grid/building designers.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , ,