Article ID Journal Published Year Pages File Type
700237 Control Engineering Practice 2013 10 Pages PDF
Abstract

In this paper, a nonlinear fault diagnosis scheme is established for the hot strip mill process (HSMP). In HSMP, the faults affecting quality index are denoted as quality-related faults, which should be taken care as soon as possible. Projection to latent structures (PLS) is a basic model for quality-related fault detection in linear processes. In the presented work, a total kernel PLS (T-KPLS) model is utilized for modeling and monitoring HSMP, which is a typical nonlinear process. However, diagnosis tools have not been developed aiming at the nonlinear case based on T-KPLS model. Motivated by the successful use of contribution plot for the linear case, a contribution rate plot is proposed to extend contribution plots to the nonlinear case. In the end of this paper, the proposed method is applied to the hot strip mill process effectively.