Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
701881 | Diamond and Related Materials | 2011 | 4 Pages |
Abstract
We report measurements of energy dissipation in single crystal diamond annular plate resonators for temperatures ranging from 4 to 300 K. An order of magnitude reduction in dissipation is observed as the temperature is lowered from room temperature (1/Q = 5 × 10−4) to 30 K (1/Q = 5 × 10−5).
► Single crystal diamond annular plate resonators; ~ 10 μm diameter, ~ 175 nm thick. ► ~ 50 MHz fundamental and 177 MHz overtone studied. ► Dissipation drops an order of magnitude with temperature from 300 K to 30 K. ► Dissipation up to factor of 5 lower than for ~ 50 MHz NCD or UNCD resonators.
Related Topics
Physical Sciences and Engineering
Engineering
Electrical and Electronic Engineering
Authors
Matthew P. Ray, Tatyana I. Feygelson, James E. Butler, Jeffrey W. Baldwin, Brian H. Houston, Bradford B. Pate, Maxim K. Zalalutdinov,