Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7044919 | Applied Thermal Engineering | 2018 | 24 Pages |
Abstract
In this paper attention is devoted to the drop-in substitution of HFC134a with HFO refrigerant fluids in a domestic refrigerator. An experimental evaluation of the environmental impact in term of the greenhouse effect of the substitution of HFC134a with HFOs has been reported. The greenhouse effect is accounted for the experimental evaluation of the LCCP (Life Cycle Climate Performance) index. The refrigerant fluids that have been tested as a drop-in are: pure HFO1234yf, the mixture HFO1234yf/HFC134a (90/10% in weight), pure HFO1234ze (E) and the mixture HFO1234ze (E)/HFC134a (90/10% in weight). The plant working with pure HFOs or with both mixtures achieves the same temperature levels of HFC134a in the freezer and the refrigerator cabinet. The experimental results clearly show that the lower environmental impact in term of global warming can be achieved with both mixtures. The lower LCCP index can be obtained with HFC134a/HFO1234yf (with a 17% reduction respect to HFC134a).
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
C. Aprea, A. Greco, A. Maiorino,