Abstract
Field test was performed on the high level water collecting wet cooling towers (HWCTs) of a 1000â¯MW unit to investigate ventilation performance under crosswind conditions, the circumferential inflow air distribution rules and ventilation rate were analyzed in this paper. The test results manifest that crosswind destroys the uniformity of circumferential inflow air, increases the wind velocity in the windward side, and reduces wind velocity in the lateral and leeward side. Moreover, the uniformity coefficient of circumferential inflow air and ventilation rate continuously decrease with the increasing of crosswind velocity. In this study, θ represents the angle between cross walls and crosswind direction. When crosswind velocity reaches to 3.74â¯m/s, the uniformity coefficient decreases to 0.61 and 0.49 under θ1â¯=â¯5° and θ2â¯=â¯35°. Compared with 0.28â¯m/s condition, the ventilation rate reduces by 30.13% under θ1â¯=â¯5° and 34.36% under θ2â¯=â¯35°. Additionally, at the same crosswind velocity, the smaller the θ is, the better the ventilation performance becomes. Compared with θ2â¯=â¯35°, the uniformity of circumferential inlet air is better and the ventilation rate is larger than that under θ1â¯=â¯5° condition.