Abstract
Considering the requirement of special heat transfer position in practical application, a closed-loop pulsating heat pipe (CLPHP) with partial horizontal structure (horizontal evaporator and condenser configuration) is proposed, and the features of present CLPHP including vertical start-up height and thermal performance, are numerically investigated. The volume of fluid (VOF) model and the continum surface force (CSF) model are adopted in numerical process. The reliability of present numerical method is verified by comparing the results of vertical CLPHP using present method with those of available literature. The results indicate that the proposed CLPHP can start up and running normally, as long as the height difference between the evaporator and condenser section is more than a threshold which is defined as the critical vertical start-up height. Furthermore, the dimensionless critical vertical start-up height under the conditions of various heating power and filling ration is obtained. When the filling ratio of present CLPHP remains constant, it's found that the thermal resistance reduces with the increase of the height difference between the evaporator and condenser section, which results from the greater gravity force effect. In addition, with the argument of heating power, the thermal performances of present CLPHP with different height difference are becoming the same gradually on account of the effect of latent heat and sensible heat transport.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, ,