Abstract
In addition, cost-benefits evaluation shows that triple-U shaped ground heat exchanger has highest economic performance, followed by double-U, spiral and double-W type. However, pipe material is only a small consists of the total installation costs. Hence, thermal efficiency is a more important factor to consider than pipe costs in practical application.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Jin Luo, Haifeng Zhao, Shuqiang Gui, Wei Xiang, Joachim Rohn, Philipp Blum,