Article ID Journal Published Year Pages File Type
7047526 Applied Thermal Engineering 2016 9 Pages PDF
Abstract
The average volumetric heat transfer coefficient in a spray column liquid-liquid-vapour direct contact evaporator has been experimentally investigated. The experiments were carried out utilising a cylindrical Perspex tube of diameter 10 cm and height and 150 cm. Saturated liquid n-pentane and warm water at 45 °C were used as the dispersed and continuous phases, respectively. Three different dispersed flow rates (10, 15 and 20 L/h) and four different continuous phase flow rates (10, 20, 30 and 40 L/h) were used in the study. The effect of different parameters, such as the initial drop size, continuous and dispersed phase flow rates and sparger configuration, on the average volumetric heat transfer coefficient in the evaporator was studied. The results showed that the average volumetric heat transfer coefficient was reduced as the initial drop size increased. Also, both the continuous phase and the dispersed phase flow rates have a significant positive impact on the average volumetric heat transfer coefficient.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , ,