Abstract
The current paper studies the effect of different retrofitting measures for reducing cooling load of buildings in hot climate. A common type of residential house with dimension of 12 × 12 × 3 m in Qatar was chosen as a case study. Five energy retrofitting measures of the building envelope have been considered in this study: (1) U-value of the external shell, (2) indoor set-temperature, (3) lighting efficacy, (4) the color of external shell, and (5) windows' quality. Hourly analysis program was used for calculating the cooling load of the case study. The anticipated costs associated with the implementation of the retrofitting measures were calculated based on the local current prices in Qatar. Simple payback period for each measure was assessed in the present study. The simulations show that the energy saving of 53% can be obtained at the working conditions of Qatar. The payback period of the examined measures is relatively short and varies between 0.5 and 4 years.