Article ID Journal Published Year Pages File Type
7048890 Applied Thermal Engineering 2015 36 Pages PDF
Abstract
The purpose of this investigation is to develop a mathematical procedure to solve the nonlinear axially symmetric potential flow equation applied to the prediction of the mass ratio of a ejector operating in the double choked regime. An iterative procedure based on adding error residuals upon the linearized solution has been devised as the solving scheme. Discrepancies between nonlinear and linear solutions and the application of the nonlinear method to experimental results, both from an in-house investigation and from elsewhere, are reported. The maximum deviation between the linearized and non-linearized solutions is below 2% for the cases considered, which confirms the validity of the linearized solution. On the other hand, the average deviation between the nonlinear and experimental mass ratio is below 7%, which proves the applicability of the model.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , ,