Article ID Journal Published Year Pages File Type
7110388 Control Engineering Practice 2018 9 Pages PDF
Abstract
A model based on-line foul monitoring approach for a power plant reheater is proposed. Dual Extended Kalman Filter (DEKF) is designed to estimate the model parameters that influence fouling. Based on the estimated parameters the performance index (Cleanliness Factor) is obtained to retrieve the extent of fouling on reheater. The simulation and experimental validation using power plant data shows the efficacy of DEKF over conventional Joint-EKF (JEKF) in estimating the model parameters. The outcome of the work will assist in soot blow scheduling for reheater by perceiving the fall in cleanliness factor and will also help in analysing its impact on heat transfer efficiency.
Related Topics
Physical Sciences and Engineering Engineering Aerospace Engineering