Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
742491 | Sensors and Actuators B: Chemical | 2012 | 5 Pages |
Abstract
A fiber sensor based on polarization-maintaining fiber loop mirror (FLM) for liquid refractive index absolute measurement is described. Two sections of polarization maintaining fibers (PMFs) with different length were inserted into the FLM. One section of PMF was chemical etched for liquid refractive index measurement and the other one for reference. Liquid refractive index absolute measurement can be obtained by detecting the interference wavelength difference corresponding to the two sections of PMFs. High sensitivity of 63.82 ± 0.04 nm/RIU (refractive index unit) and a resolution of 3.14 × 10−4 RIU were obtained for the proposed liquid refractive index sensor.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Chuan Zhong, Changyu Shen, Yang You, Jinlei Chu, Xin Zou, Xinyong Dong, Yongxing Jin, Jianfeng Wang,