Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7703141 | Ultrasonics Sonochemistry | 2018 | 40 Pages |
Abstract
Melamine terephthaldehyde modified graphene oxide (MTR-GO) with optimum content was easily prepared via ultrasonication method and used as anti-corrosion additive for Poly (vinyl chloride) (PVC). The effects of ultrasonicated MTR-GO on the mechanical, chemical and thermal resistance of the PVC were thoroughly studied. Change percentage of tensile strength and weight change percentage of PVC (P) and PVC/MTR-GO nanocomposite (PN) in acetone and sodium hypochlorite (NaClO) media at two different exposure temperature (20â¯Â°C and 50â¯Â°C) were examined. The PN sample showed lower change loss percentage of tensile strength in acetone uptake as compared with P sample at 20â¯Â°C. In higher temperature (50â¯Â°C), P sample was decomposed while PN still showed tensile data. The change loss percentage in tensile strength of PN sample showed 13% change at 50â¯Â°C in sodium hypochlorite while P sample showed 63% change for the parameter. Protective behavior of MTR-GO nanofiller on PVC matrix against thermal HCl releasing was investigated by Congo red tests. The results showed that the nanocomposite release less amount of HCl as compare to the neat PVC.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Chemistry (General)
Authors
Mahroo Khaleghi, Khadijeh Didehban, Meisam Shabanian,